8. Are all of the required dimensions shown? Arethere superfluous dimensions that are not needed?9. Are all necessary explanatory notes given? Areall general notes in their proper location on the drawing?10. Are terms and abbreviations consistent withmilitary standards? Are the abbreviations (especiallyunusual ones) explained in a legend?In addition to all of the above, you also should beconstantly alert to misspellings and the improper use ofphases and statements. Oftentimes, phases andstatements that are used in common practice are notacceptable for use in project drawings. Listed below aresome of the most common errors found in projectdrawings. (A correction follows each incorrect phraseor grouping of phrases.)1. Incorrect:Correct:2. Incorrect:Correct:3. Incorrect:Correct:4. Incorrect:Correct:5. Incorrect:Correct:6. Incorrect:Correct:“As instructed by the architect.”“As directed” (Note, however, thatyou should avoid using this type oflanguage since it indicates un-certainty as to what the requirementsare.)“As approved by the architect.”“As approved.”“By the Navy.”“By others.”“By the Government.”“By the electrical contractor.”“By the plumber.”“By the plumbing contractor.”(Usually no statement is necessarysince the government recognizes onlythe prime contractor.)“12 gauge zinc-coated steel flashing.”“copper flashing.”“Metal flashing.” (Metals are referredto only as metal and not as a particularkind or gauge. Type and weightshould be covered in the projectspecifications.)“Formica.”“Laminated plastic.” (Proprietary orbrand names are not permitted.)Q1.Q2.Q3.Q4.Q5.Q6.Q7.Q8.Q9.Q10.QUESTIONSInto what drawing divisions should you placedrawings that &scribe each of the followingtypes of information?a.b.c.d.Number and size of treads and risers in astairwayBearing and distance of property linesEquipment for HVAC systemsSteel reinforcing requirements for beamsand columnsIn which of the following ways does a forced-airfurnace differ from a gravity warm-air furnance?a. It uses a fan for circulation of the heated airb. It requires smaller ductworkc. It can be equipped with cooling coilsd. All of the aboveIn what primary way does a heat pump differfrom a window air-conditioning unit?“Effective temperature” is the net effect of threefactors that affect human health and comfortWhat are those three factors?What NAFACENGCOM publication providesbasic guidance and policy for the preparation ofproject drawings?When using the international system of units,what SI unit (meter, millimeter, or centimeter)should you NOT use for project drawings ?What title block format must you use whenpreparing NAVFACENGCOM project drawingson 22- by 34-inch tracing paper?For a large set of project drawings, what lettershould you place near the title block to designatethose sheets of drawings that are in the plumbingdivision?When is it permissible for you to reuse aNAVFAC drawing number?What is the primary reason that you shouldalways check line weights when checking andediting drawings?4-12
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business